Pharmaceutical, biotechnology and Anaerobic research glove box solution
Adjustable atmosphere environment, clean maintenance, and safe sample operation and observation platform to meet the needs of hypoxic/anaerobic research and biological process development.
Precisely control oxygen concentration to meet research needs from hypoxia to anaerobic
Controllable temperature and humidity to stably support cell culture and sample activity
Clean ventilation structure, easy to clean and disinfect, reducing the risk of contamination
Multi-device and data integration to improve research efficiency and traceability
Sample protectionMaintain a low-oxygen/anaerobic environment to protect samples and intermediate products
Personnel protectionProvide safe protection functions for researchers
Environmental protectionNo exposure to external BMC environment or biological safety cabinet
Typical requirements
Anaerobic/low oxygen atmosphereStably control O₂ content
Temperature and humidity controlMaintain cell/sample viability
Cultivation equipment integrationIncubator, microscope, etc.
Sample transferSecure transfer in/out
Surface cleaning and disinfectionEasy to clean and disinfectable
Positive pressure/negative pressureFlexible control of cabin pressure
HEPA filtrationClean gas circulation
Data recordsReal-time monitoring and tracing
Typical process
Samples and instruments Preprocessing
→
Transfer to transition cabin
→
Atmosphere creation
→
Cultivation/experimental operations
→
Observation and recording
→
Sealed transfer
→
Cleaning and Disinfection Environment recovery
Recommendation system
GBP750S-2 single station purification glove box
The sealed box and gas purification cycle provide a stable and clean atmosphere for anaerobic or low-oxygen operations of oxygen- and water-sensitive samples.
800 × 650 × 650 mm sealed working chamber, which uses vacuum evacuation and inert gas backfilling to reduce the contact between the sample and the air.
Stainless steel closed operating chamber
Vacuum evacuation and inert gas backfill
Suitable for sample processing and material preparation
The transparent and sealed working space is convenient for observation and operation, and can be used for the processing, transfer and teaching experiments of air and humidity sensitive samples.
The program control unit realizes automatic control and detection of equipment operation.
Box manual/automatic gas replacement
Supports replacing the cabinet air with inert gas or nitrogen before first use.
Transition cabin manual/automatic gas replacement
When materials enter the box, the transition cabin can be manually or automatically replaced with gas.
Gas purification control
It can automatically maintain the set atmosphere conditions in the box, or switch to manual control.
Foot-operated air pressure control
Use the foot controller to control the inflating or pumping of the box and adjust the air pressure of the box.
Purge System Restore
After setting the reduction conditions, the system can automatically complete the purification material reduction process.
Online working condition detection
Monitor the working status of components, assist in locating functions and source of component failures.
System parameter settings
Realize corresponding working conditions and function settings by setting system parameters.
Data logging function
Record equipment operating parameters for traceability and monitoring of experiments or production processes.
Control air circuit backup
When the control gas source is temporarily cut off or insufficient, the backup control gas can ensure that the equipment continues to work.
Multi-level security system
Provides multi-level safety prompts, alarms and prohibition functions to ensure the safety of personnel and equipment.
Purification cycle obstruction protection
When the circulation is blocked, it prompts an alarm and adjusts the wind speed to protect the motor. It also assists in identifying pipe or filter blockages.
System configuration
Configuration and quantity
Technical parameters
Remarks
Standard transition cabin 1 piece
DN385 × 588 mm
Right side of the cabinet; SUS304 stainless steel, aluminum alloy door cover, built-in movable drawer and door opening assist device.
Tool transition cabin 1 piece
DN150 × 350 mm
The right side of the box; made of SUS304 stainless steel, can be made as required.
1 piece of shelf
Double layer
Back-mounted.
Box rack 1 piece
Height 900 mm
Equipped with swivel casters; a purification system is integrated into the right rack.
Transparent visual panel
Thickness 12 mm
Double-layer laminated tempered glass.
4 gloves
Thickness 0.4 mm
Butyl synthetic rubber.
1 power socket
220 V, 10 A, 8 holes
Located inside the box, it supplies power to the electrical appliances in the box.
Lighting system
Fluorescent tube
Provides lighting inside the box.
3 sets of spare interfaces
KF40
Gas or liquid access device; SUS304 stainless steel, equipped with quick connector.
1 vacuum pump
D16C, pumping volume 4 L/S
Equipped with oil mist filter.
2 HEPA filters
Filter precision 0.3 μm
It is used to filter dust in the box and protect the ventilation pipes from being unobstructed.
2 vacuum gauges
Mechanical dial display
Measure the vacuum degree of the standard transition cabin and tool transition cabin.
1 pressure gauge
Mechanical dial display
Measure the air pressure of the box.
Foot controller 1 piece
Double pedal type
Control the gas replenishment and emptying of the cabinet.
Control system
Color touch screen: 6 inches
Touch screen and PLC are configurable; support multi-language operation interface switching.
1 pressure sensor
-2500 ~ 2500 Pa (relative pressure)
Touch screen display.
Moisture analyzer 1 piece
0 ~ 1000 ppm, accuracy 0.1 ppm
Touch screen display.
Oxygen transmitter 1 piece
0 ~ 1000 ppm, accuracy 0.1 ppm
Touch screen display.
Gas purification system
Single purification column
It has water and oxygen removal functions and is integrated into the cabinet frame.
Organic solvent adsorption system
21 L
Installed in the glove box pipeline to absorb solvent gas generated during use and protect purification materials.
Key control objectives reference
Target oxygen concentration
≤ 0.1 ppm
(Typical value)
Temperature and humidity range
15 ~ 35 ℃
20 ~ 60% RH
HEPA rating
H14
(Intake/Exhaust)
Pressure control
+10 ~ +30 Pa
(relatively external)
Data records
≤ 30 times/hour
(adjustable)
Typical application scenarios
Anaerobic culture
Provides a stable, anaerobic culture environment for anaerobic microorganisms to ensure the accuracy of bacterial growth and metabolism research.
Hypoxic cell research
Precisely control the hypoxic atmosphere, simulate the physiological/pathological hypoxic microenvironment, and support the study of cell functions and signaling pathways.
Biological sample processing
Sample preparation, packaging and transfer are performed in a clean, controlled atmosphere to reduce the risk of contamination and oxidation.
Medical environment simulation
Simulate the pharmaceutical production and storage environment to evaluate the stability of materials, packaging and preparations under specific atmospheres.
Why choose TENCAN
Customized engineering capabilities
In-depth understanding of process requirements and providing customized engineering services from solution design to implementation.
Device integration experience
Years of experience in glove box and laboratory system integration, the solution is mature and reliable.
Atmosphere control and testing
Core atmosphere control and detection technology, accurate data and stable operation.
Installation training support
The professional engineering team provides atmosphere debugging and operation training to get started quickly.
Global delivery and after-sales
Global delivery network and localized services, timely response and worry-free after-sales.
Product introduction
Single-Station Single-Sided Glove Box with Gas Purification System
Single-station single-sided glove box with gas purification provides a controlled inert atmosphere for battery, materials, chemical and laboratory applications.
Two-Station Single-Sided Glove Box with Gas Purification System
Two-station single-sided glove box with gas purification provides a controlled inert atmosphere for battery, materials, chemical and laboratory applications.
Two-Station Single-Sided Split-Type Glove Box with Gas Purification System
Two-station single-sided split-type glove box with gas purification provides a stable inert atmosphere for battery, materials, chemical and laboratory research.
GBV-1 stainless steel vacuum glove box creates a controlled inert atmosphere for handling air- and moisture-sensitive materials in laboratory applications.
GBT acrylic glove box provides a transparent enclosed workspace for handling air- and moisture-sensitive materials, with multiple sizes and vacuum options.
Disinfection methods and materials compatible:Choose materials and components that can withstand disinfectants and high temperatures.
Dead corners inside the cabinet:Reasonable rounded corner design and detachable structure avoid cleaning blind spots.
Gloves and sealing materials:Focus on long-term sealing performance, chemical resistance and ease of replacement.
Exhaust gas treatment:Choose appropriate filtration and treatment methods based on the type of process gas.
Sample transfer method:Choose sealed transfer chambers or rapid transfer interfaces to reduce exposure risks.
Whether sterility verification is required:Clear the scope and methods of verification (such as culture medium/challenge test, etc.).
Whether GMP/pharmacopoeia/biosafety regulations are involved:Plan ahead for compliance design and documentation requirements.
FAQ
Anaerobic/hypoxic systems place more emphasis on settable biological research atmosphere, culture and cleaning processes; high-purity glove boxes usually place more emphasis on extremely low water and oxygen indicators. Actual solutions can be combined according to sample, personnel and environmental protection objectives.
Yes. Through oxygen sensor, gas mixing and automatic air supply/exhaust control, stable control of hypoxic to anaerobic atmosphere can be achieved according to the target range, and data recording can be configured.
Supported. It can integrate temperature and humidity sensing, heating/cooling, humidification/dehumidification and other modules. The specific control range and accuracy need to be determined based on the cultivation process and indoor environment.
Cleaning, filtration, materials, cleaning, disinfection and verification design can be carried out according to the aseptic operation objectives; whether it meets the requirements of specific production regulations should be confirmed according to the GMP, pharmacopoeia and verification specifications applicable to the project.
Positive pressure is usually chosen when sample protection is the main focus; negative pressure or partitioned pressure difference can be used when it is necessary to reduce the risk of harmful substances escaping to the outside. The final determination should be based on the protection objects, gas properties and laboratory facility conditions.
It is recommended to use rounded inner cavities, easy-to-wipe surfaces and removable parts, and choose wiping, spraying or other compliant disinfection methods based on material compatibility. A verification interface can be reserved if necessary.
Solution Consultation
Find the Glove Box Solution That Fits Your Needs
Tell us about your application, chamber size, H2O/O2 specifications, or integration requirements, and our engineers will recommend a suitable configuration.
Standard products and customized integration available
Your requirement details are kept strictly confidential